How to choose a PoE switch: ports, power and distance
The easiest way to connect IP cameras is PoE (Power over Ethernet): one network cable carries both data and power, so no camera needs its own socket or power supply. For that you need a PoE switch. Look at four things when choosing one.
1. Number of ports
One PoE port per camera, plus one regular (uplink) port for the recorder or router. Leave 1–2 spare ports for future cameras.
- 4 cameras — NS-0105P-35 (4 PoE + 1 uplink) or DS-3E1506P-EI/M (4 PoE + 2 gigabit ports);
- 8 cameras — DS-3E1510P-EI/M (8 PoE + 2 gigabit ports);
- large sites — DS-3E0526P-E/M (24 gigabit PoE ports + 2 fibre ports).
2. PoE standard
| Standard | Power per port | For |
|---|---|---|
| IEEE 802.3af (PoE) | up to 15.4 W | Regular cameras, intercoms |
| IEEE 802.3at (PoE+) | up to 30 W | PTZ cameras, cameras with heaters |
| IEEE 802.3bt (Hi-PoE) | 60–90 W | High-power PTZ, multi-sensor cameras |
For example, on the DS-3E1310HP-EI ports 1–2 deliver up to 90 W (Hi-PoE) and the rest up to 30 W — handy for one powerful PTZ plus several regular cameras.
3. PoE power budget — the most common mistake
The total power a switch can deliver across all ports is limited. Look for "PoE Power Budget": NS-0105P-35 — 35 W, DS-3E1506P-EI/M — 45 W, DS-3E1510P-EI/M — 60 W, DS-3E0526P-E/M — 225 W.
Calculation: sum of the cameras' maximum consumption + 20–30% headroom. Example: 8 × IPC-T280HA-LUF/SL (up to 8 W each with the white light on) = 64 W. That is too much for a 60 W switch — at night, when all lights switch on at once, cameras may reboot. Choose a switch with a larger budget.
4. Distance
The standard run for network cable (UTP Cat5e/Cat6) is up to 100 m. Many PoE switches have an extended-range mode (for example, on all PoE ports of the NS-0105P-35) — speed drops, but it is still enough for a camera. Beyond that, use fibre.
Unmanaged or "Smart"
An unmanaged switch works out of the box — enough for a home or small shop. "Smart" models add features: PoE Watchdog on the DS-3E1510P-EI/M automatically restarts a camera that stops responding, and port isolation improves network security.
Summary
- Ports: number of cameras + uplink + 1–2 spare.
- Standard: 802.3af for regular cameras, at least 802.3at for PTZ.
- Budget: 20–30% above the cameras' total power.
- Distance: up to 100 m; beyond that, extended mode or fibre.
All models: unmanaged PoE switches and Smart PoE switches.